Name
Bytes
Function
Default
DS
IX
SX
RO
2
Rated output
4E20h
80h
310Ah
08h
ZB
2
Zero balance
0000h
80h
310Ch
09h
GN
2
Gain
1000h
80h
310Eh
0Ah
TA
2
Tara
0000h
80h
3110h
0Bh
NL
2
Nominal load
0002h
80h
3112h
0Ch
SF
2
Scale factor
03E8h
80h
3114h
0Dh
SST
2
Steady state tolerance
0005h
80h
3116h
0Eh
SSW
2
Steady state window
03E8h
80h
3118h
0Fh
RL
4
Reference load
00000100
80h
311Ah
10h
*) This record set may only be transferred at STOP state.
Byte
Bit 7 ... 0
0
n
Diagnostic interrupt
–
00h: disable
–
40h: enable
n
Here you activate respectively de-activate the diagnostic function.
Byte
Bit 7 ... 0
0
n
Power supply
–
00h: 2.5V
–
01h: 5V
–
02h: 7.5V
–
03h: 10V
–
04h: 12V
n
Here you can specify the power supply for the excitation voltage U
EXC
, which the
module provides via the pins EXC+ und EXC-.
Please always use the excitation voltage U of the module
EXC
! The con-
nection of strain gauge DMS sensors with external power supply is not
possible.
Byte
Bit 7 ... 0
0...1
n
Interval for the calibration.
–
Calibration interval as 100ms value
–
00h: de-activates the calibration
n
By setting a calibration interval as 100ms value, the self-calibration is always per-
formed after this time.
n
With the self-calibration the internal offset and gain error may be compensated.
n
There is always the entire signal path including all passive components checked.
DIAG_EN Diagnostic inter-
rupt
UEXC select power supply
CAL Calibration interval
VIPA System SLIO
Analog Input
031-1CA20 - AI 1x16(24)Bit Strain gauge (DMS) > Parameter data
HB300 | SM-AIO | | en | 17-05
182