For wires with a core cross-section of 0.08mm
2
up to 1.5mm
2
.
Pos.
Function
Type
Description
1
SIG+
I
+ Signal of the differential voltage U
SIG
of the measuring bridge
2
SIG-
I
- Signal of the differential voltage U
SIG
of the measuring bridge
3
EXC-
O
- Signal of the excitation voltage U
EXC
4
Shield
---
Connection for cable shield
5
SEN+
I
+ Sensor of the excitation voltage U
SEN
6
SEN-
I
- Sensor of the excitation voltage U
SEN
7
EXC+
O
+ Signal of the excitation voltage U
EXC
8
Shield
---
Connection for cable shield
O: Output, I: Input
Please always use the excitation voltage U
EXC
of the module! The con-
nection of sensors with external power supply is not possible.
3.16.1
Connection variants
The following table shows the properties of the sensors, which can be used with the 6
wire measurement.
Pin assignment
6 wire measurement
VIPA System SLIO
Analog Input
031-1CA20 - AI 1x16(24)Bit Strain gauge (DMS) > Connection variants
HB300 | SM-AIO | | en | 17-05
173