General Lists
Name
Description
BO Slot X5.BO 1
Signal: Binary Output Relay
BO Slot X5.BO 2
Signal: Binary Output Relay
BO Slot X5.BO 3
Signal: Binary Output Relay
BO Slot X5.BO 4
Signal: Binary Output Relay
BO Slot X5.DISARMED!
Signal: CAUTION! RELAYS DISARMED in order to safely perform maintenance while
eliminating the risk of taking an entire process off-line. (Note: The Self Supervision
Contact cannot be disarmed). YOU MUST ENSURE that the relays are ARMED AGAIN
after maintenance
BO Slot X5.Outs forced
Signal: The State of at least one Relay Output has been set by force. That means that
the state of at least one Relay is forced and hence does not show the state of the
assigned signals.
BO Slot X6.BO 1
Signal: Binary Output Relay
BO Slot X6.BO 2
Signal: Binary Output Relay
BO Slot X6.BO 3
Signal: Binary Output Relay
BO Slot X6.BO 4
Signal: Binary Output Relay
BO Slot X6.DISARMED!
Signal: CAUTION! RELAYS DISARMED in order to safely perform maintenance while
eliminating the risk of taking an entire process off-line. (Note: The Self Supervision
Contact cannot be disarmed). YOU MUST ENSURE that the relays are ARMED AGAIN
after maintenance
BO Slot X6.Outs forced
Signal: The State of at least one Relay Output has been set by force. That means that
the state of at least one Relay is forced and hence does not show the state of the
assigned signals.
Event rec.Res all records Signal: All records deleted
Disturb rec.recording
Signal: Recording
Disturb rec.memory full
Signal: Memory full
Disturb rec.Clear fail
Signal: Clear failure in memory
Disturb rec.Res all
records
Signal: All records deleted
Disturb rec.Res rec
Signal: Delete record
Disturb rec.Man Trigger
Signal: Manual Trigger
Disturb rec.Start1-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start2-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start3-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start4-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start5-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start6-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start7-I
State of the module input:: Trigger event / start recording if:
Disturb rec.Start8-I
State of the module input:: Trigger event / start recording if:
Fault rec.Res rec
Signal: Delete record
Trend rec.Hand Reset
Hand Reset
SSV.System Error
Signal: Device Failure
SSV.SelfSuperVision
Contact
Signal: SelfSuperVision Contact
Scada.SCADA connected At least one SCADA System is connected to the device.
1205
MCDLV4
DOK-HB-MCDLV4-2E
Содержание HighPROtec MCDLV4
Страница 1: ...Manual Line Differential Protection MCDLV4 Software Version 3 4 a DOK HB MCDLV4 2E Revision A English...
Страница 3: ...Order Code Order Code 3 MCDLV4 DOK HB MCDLV4 2E...
Страница 47: ...Installation and Connection 47 MCDLV4 DOK HB MCDLV4 2E...
Страница 164: ...Input Output and LED Settings 164 MCDLV4 DOK HB MCDLV4 2E...
Страница 433: ...Parameters 433 MCDLV4 DOK HB MCDLV4 2E...
Страница 457: ...Device Parameters 457 MCDLV4 DOK HB MCDLV4 2E...
Страница 473: ...Blockings 473 MCDLV4 DOK HB MCDLV4 2E...
Страница 822: ...Protective Elements Name Description Profibus Scada Cmd 16 Scada Command 822 MCDLV4 DOK HB MCDLV4 2E...
Страница 988: ...Protective Elements 988 MCDLV4 DOK HB MCDLV4 2E P P Q P Q P Q Q Q P S S...
Страница 989: ...Protective Elements 989 MCDLV4 DOK HB MCDLV4 2E Pr Q P Q P Qr...
Страница 1023: ...Protective Elements 1023 MCDLV4 DOK HB MCDLV4 2E...
Страница 1070: ...Supervision 1070 MCDLV4 DOK HB MCDLV4 2E...