Chapter - 2
MNL000420.doc
Revision 1
04/08/2019
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
-
2
Versum Materials Confidential
2.1
Equipment and Features
2.1.1
Physical Description
Table 2-1
ATCS15/VaporGuard® Comparisons
The VaporGuard® is available in the following models:
*Maximum temperature indicated has been tested under ideal benchtop conditions.
Actual maximum temperature is molecule and application dependent. In most cases, 80-
90C is appropriate.
Existing ATCS
VaporGuard®
Models
Temperature
Range
Equivalent Model
Temperature range*
ATCS 15
+10 °C to 60 °C
VG600 N/W
+10 °C to +60 °C
ATCS 15-HT
+40 °C to 90 °C
VG600 NHT/WHT
+10 °C to +115 °C
ATCS 15-SS
+10 °C to 60 °C
VG600 N/W
+10 °C to +60 °C
ATCS 15-HT SS
+40 °C to 90 °C
VG600 NHT/WHT
+10 °C to +115 °C
ATCS 15-TLC
ATCS 15 TLCHF
ATCS 15-TLCHFC
+10 °C to 22 °C
VG300 N/W factory
configured for
Trans-LC™
+10 °C to 22 °C
ATCS 15-TLCHFCK
+10 °C to 20 °C
VG300 N/W factory
configured for
Trans-LC™
+10 °C to 22 °C