MNL000424.doc
Revision 00
08/26/2016
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
-
1
Chapter
6
System Installation
6.1
Introduction
This section provides instructions for installation of the VaporGuard® System. Read
the entire section before proceeding with the installation.
6.2
Placement of the System
Figure 6-1 shows the space requirements necessary for the complete system and the
integral components. Also shown are the dimensions for securing the system onto a
shelf. The recommended placement height for the Source Cup Assembly is between
35” (88.9 cm) and 50” (127 cm) above the floor. This will allow for viewing of the LCD
display and access to the top of the Source Cup Assembly. The placement height for
the optional Remote Display Module is between 52” (132 cm) and 58” (147 cm) above
the floor. The placement of the LCD displays should allow for a viewing distance that is
between 18 inches (45.7 cm) and 30 inches (76.2 cm).
CAUTION
The VaporGuard® should be securely bolted to a shelf to provide protection during
a seismic disturbance.