voltage measurement for temperature. The entries to the right of the “OS” and
“GN” represent the offset and gain parameters respectively.
L # # # % O S
# # #
G N
# # #
T # # #
º
O S
# # #
G N
# # #
7.
Adjust temperature parameter to read maximum 110º. Measure the voltage
output and adjust the gain parameter “GN” until the output reads 5.00VDC ±0.05.
8.
Use the left arrow to move to the temperature reading and adjust the display to
read 12º. Verify that the output reading is 0.5VDC ±0.05. Adjust the offset
parameter “OS” as required.
9.
Adjust temperature parameter back to 110º. Measure the voltage output and
adjust the gain parameter “GN” until the output reads 5.00VDC ±0.05.
10.
Adjust the display to read 0º. Verify that the output reading is 0.0 VDC ±0.05.
Adjust the offset parameter “OS” as required.
11.
Repeat steps 9 and 10 until the adjustments are no longer required.
12.
The user may check any percentage value in between for the corresponding
output. For example, 60ºC will produce a 2.5VDC output.
13.
Move the DMM positive lead to J5-20 on the J5 connector of the Power Supply
Module. The DMM setting remains the same.
14.
Adjust the “L” level parameter to read maximum 100%. Measure the voltage
output and adjust the gain parameter “GN” until the output reads 5.00VDC ±0.05.
15.
Use the left arrow to move to the level reading and adjust the display to read 10%.
Verify that the output reading is 0.5VDC ±0.05. Adjust the offset parameter “OS”
as required.
16.
Adjust the level parameter back to 100%. Measure the voltage output and adjust
the gain parameter “GN” until the output reads 5.00VDC ±0.05.
17.
Adjust the display to read 0º. Verify that the output reading is 0.0 VDC ±0.05.
Adjust the offset parameter “OS” as required.