Gently grasp the Bubbler by the two valve stems (not the valves) and lower it
into the Source Cup Assembly. Exercise caution when handling Bubbler.
2.
The Bubbler should be positioned only one way. With the system facing
forward, the thermowell should be directly on top of the magnet in the base of
the Source Cup Assembly. This is important for the proper operation of the
liquid level sensors. The system will alert the user with a short beep when the
probe has been installed properly, refer to figure 6-16.
Figure 6‐16a
Bubbler Positioning in Source Cup Assembly (Model VG300)
3.
Turn on power to the VaporGuard® SW1 on Power Supply Module.