Chapter 14: Troubleshooting
General Precautions
To prevent critical situations it is important that all alarms, warnings, and precautions for safe
operation are observed. While setting up the X
TRA
, the operator should always check the unit
thoroughly.
Chapter 1: Introduction and Safety
regarding warnings and cautions related to the use and
management of the X
TRA
equipment.
Supervision and Checks
During the operation of the unit, a number of tests are carried out by the system to check the safety,
reliability, and performance of the equipment. If functional anomalies are detected, suitable safety
measures are immediately taken.
Only one alarm or warning can be active at once. If more than one anomalous situation is detected
simultaneously, the one with the higher priority will determine the machine’s response.
When an alarm or warning is issued, the system enters a safe state (corresponding to the stopped
Ready Screen): the pump and centrifuge are halted, the clamps closed, and the lid lock opened.
Alarms and Warnings
The X
TRA
uses audible and visual signals to inform the user about the occurrence of meaningful events.
Such events may be grouped into three classes:
•
Warnings
– refer to detection of events that can be interesting for the user and in some cases
can imply the interruption of the process in progress. Prosecution of process interrupted by the
occurrence of a warning requires confirmation from the operator.
•
Alarms
– refer to detection of events that imply interruption of the process in progress. Detection
of these events is usually accompanied by suggestions for the operator to perform checks or
actions. Process prosecution after occurrence of this kind of information signals always requires
the operator confirmation.
•
Fatal Errors
– signify detection of unrecoverable hardware anomalies. Technical intervention may
be required to recover the system from a fatal error.
Содержание 75220
Страница 1: ...Operator s Manual SOFTWARE VERSION 2 00 20077 021 US FOR US MARKET ONLY...
Страница 70: ...System Description 3 32 20077 021 US XTRA Operator s Manual...
Страница 148: ...Special Cycles 6 10 20077 021 US XTRA Operator s Manual...
Страница 156: ...Automated Functions 7 8 20077 021 US XTRA Operator s Manual...
Страница 178: ...Programmability Option 9 10 20077 021 US XTRA Operator s Manual...
Страница 206: ...Preoperative Sequestration PPP and PRP 10 28 20077 021 US XTRA Operator s Manual...
Страница 232: ...Vacuum Module 13 10 20077 021 US XTRA Operator s Manual...
Страница 260: ...Troubleshooting 14 28 20077 021 US XTRA Operator s Manual...
Страница 270: ...Maintenance 15 10 20077 021 US XTRA Operator s Manual...
Страница 282: ...A 6 20077 021 US XTRA Operator s Manual...
Страница 284: ...B 2 20077 021 US XTRA Operator s Manual...
Страница 286: ...C 2 20077 021 US XTRA Operator s Manual...
Страница 298: ...D 2 20077 021 US XTRA Operator s Manual...
Страница 302: ...E 4 20077 021 US XTRA Operator s Manual...
Страница 304: ...LivaNova Deutschland GmbH Lindberghstrasse 25 D 80939 M nchen Germany Tel 49 0 89 32301 0 Fax 49 0 89 32301 555...