SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
433
Diagnostics
11
The monitoring of the system and error diagnostics are handled in different ways:
●
Events and faults handling:
Predefined events generate a message. These messages can be distributed in different
ways:
–
Entry in the local log
–
Transfer to the Syslog server
–
Sending as e-mail
–
Sending as SNMP trap
●
Syslog:
Configures the transfer to the Syslog server
●
Port mirroring:
Mirroring of ports to analyze the data stream without disturbing operation
11.1
Diagnostics
In events and faults handling, you set the events whose messages will be distributed in one
of the available ways.
You configure the monitoring of certain system events and power supply and physical
interfaces in the Events configuration mode.
11.1.1
The "show" commands
This section describes commands with which you display various settings.
With the command
do [command]
you can execute the "show" commands in every
configuration mode.
To do this, you replace
[command]
with the "show" command that you want to execute.
Example
do show cli-console-timeout