Functions
8.2 Time stamping the input signals with IM 153-2
ET 200M
136
Operating Instructions, 12/2008, EWA-4NEB780600602-08
●
Ethernet: CP 443-1 as of FW V2.6; 6GK7443-1EX11-0XE0
Parameters to be set for Ethernet CP:
Parameter
Value
Forward time
from LAN to station
Switch on the time synchronization in SIMATIC procedure
●
PROFIBUS DP: as of CP 443-5 Extended V6.0; 6GK7443-5DX04-0XE0
(synchronization not via integrated DP interface, but via external DP master)
Parameters to be set for external DP master:
Parameter
Value
Time synchronization
from station to LAN
●
CPU, CPU 41x
Parameters to be set for CPU 41x:
Path / tab
Parameter
Value
Diagnostics / clock >
synchronization
Type of
synchronization
In the PLC
none or as slave