Remote Control Commands
R&S
®
SMBV100A
624
Operating Manual 1407.6062.32 ─ 08
............................................................................................626
[:SOURce<hw>]:FM[:DEViation]
<Deviation>
The command sets the modulation deviation of the frequency modulation in Hz. The
maximal deviation depends on the RF frequency set and the selected modulation mode
(see data sheet).
Parameters:
<Deviation>
float
Range:
0 Hz to 10 MHz
Increment: See data sheet
*RST:
10 kHz
Default unit: Hz
Example:
FM 5E3
sets the FM modulation deviation to 5 kHz.
Usage:
SCPI confirmed
[:SOURce<hw>]:FM:EXTernal:COUPling
<Coupling>
The command selects the coupling mode for the external modulation input in the case of
frequency modulation.
Note:
Coupling for external feed via input EXT MOD can be set independently for mod-
ulations AM, FM and PhiM.
Parameters:
<Coupling>
AC | DC
AC
The DC voltage component is disconnected from the modulation
signal.
DC
The modulation signal is not changed.
*RST:
AC
Example:
FM:EXT:COUP AC
selects the coupling mode AC for external frequency modulation.
Usage:
SCPI confirmed
[:SOURce<hw>]:FM:MODE
<Mode>
The command selects the mode for the frequency modulation.
SOURce Subsystem