Instrument Function
R&S
®
SMBV100A
310
Operating Manual 1407.6062.32 ─ 08
Burst Gate and Level Attenuation are set in the "Power Ramping" submenu, CW in the
"Modulation" submenu.
The source "CList/Internal" for the individual marker/control signal can be selected here
as well and will then be used in the associated menus.
SCPI command:
n.a.
Select Ramp to Edit - Digital Modulation
Graphically edit marker/control signals.
For this purpose, the cursor is set to the position where a ramp is required. The ramp is
generated by pressing Enter (e.g. clicking on the rotary knob). Any number of ramps can
be defined per marker. Each of the generated ramp positions will be saved even if the
definition of another ramp produces a low/low or high/high transition. These ramps are
displayed as dashed lines.
Existing ramps can be shifted after the cursor has been placed on the ramp and Enter
has been pressed - it then changes colour twice. The ramp is shifted by using the cursor
keys or the rotary knob. The new position is determined by pressing Enter again.
Ramps can be deleted by means of the BACKSPACE key after the cursor has been
placed on the ramp.
For detailed information on how to operate the control and marker list editor, see
ter 4.5.3, "Working with Control and Marker List Editor"
SCPI command:
n.a.
Total List Length - Digital Modulation
Enters the length of the definition range of the control list in bits. The starting value is
always bit 0. The entire definition range is displayed, i.e. the bit scale is adapted to the
entry.
With very long control lists, the displayed area can be zoomed around the current cursor
position ("Zoom in" button).
The preset functions set the ramp in the center of the currently selected area.
If the definition range is decreased, the ramps outside the range are lost.
When used, the control list is always repeated over the length of the definition range if
the length of the data list exceeds the length of the control list.
SCPI command:
n.a.
Preset Type - Digital Modulation
Activates presetting for the ramp characteristic of the selected control signal. The pre-
setting is selected with "Preset Type" and activated by means of the "Preset" button.
You can select from:
"All Up "
The marker/control signal is continuously high.
"All Down"
The marker/control signal is continuously low.
Baseband Signal - Baseband Block