![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 592](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_manual_1477734592.webp)
Remote Control Commands
R&S
®
SMBV100A
575
Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:BB:DM:CLISt:DATA
<Data>
The command sends the data to the currently selected control list. If the list already con-
tains data, it is overwritten. This command only writes data into the data section of the
file.
The values for the control signals are sent, arranged in a 8-bit value as follows:
Signal
Order
Decimal value of bits
Marker 1
Marker 2
LSBit
1
2
Burst =
LSBit
16
LevAtt1
LSBit
32
CWMod
LSBit
64
Hop
MSBit
128
The data can also be sent as a binary block, each binary block being a 2-byte value in
which the 16 bits represent the binary values (16-bit unsigned integer, 2 bytes, LSByte
first). When binary data transmission is in use, com-
mand
:SYSTem:COMMunicate:GPIB:LTERminator EOI
should be used to set the
termination character mode to ‘EOI control data message only’ so that a random LF in
the data sequence is not interpreted as End, thereby prematurely terminating the data
transmission. The command
...LTER STANdard
resets the mode.
For query purposes, the command
:FORMat ASCii | PACKed
can be used to switch
between the formats. The byte sequence is defined in the IEC bus standard as 'most
significant byte first'
Note:
C-Lists are created in binary format. However, if you need the C-List in ASCII
format, e.g. for creating a waveform file with R&S WinIQSIM2, see the example in
ter 7.3.3, "Creating an ASCII C-List Manually"
*RST
has no effect on data lists. This command is without query.
Setting parameters:
<Data>
string
Example:
BB:DM:CLIS:SEL 'c_list1'
selects the control list.
BB:DM:CLIS:DATA 0,0,0,0,8,8,8,0,0,0,0...
enters the control values in list c_list1. In the example, only ramps
for marker 4 are set.
Usage:
Setting only
SOURce Subsystem