Instrument Function
R&S
®
SMBV100A
123
Operating Manual 1407.6062.32 ─ 08
"State"
Enables the automatic compensation.
SCPI command:
"Slave Position
in Chain"
Defines the position of the slave instrument in the daisy chain, where
the slave directly connected to the master instrument is the one with
number 1, etc.
SCPI command:
"Cable Length" Sets the total length of the cable used to connect the CLK OUT and
CLK IN connectors. For the first slave in the chain, the value represents
the cable length between the master and the first slave; for the second
slave, the cable length to the first
and
to the second has to be defined,
etc.
SCPI command:
5.2.3.13
Display/Keyboard Settings
In the "Display/Keyboard Settings" menu the power-save mode and external keyboard
settings are made. It is opened using the SETUP or MENU key under "Environment".
Screen Saver Active
Activates/deactivates the screen-save mode of the display.
General Instrument Settings