Remote Control Commands
R&S
®
SMBV100A
552
Operating Manual 1407.6062.32 ─ 08
Enabling digital modulation (
BB:DM:STAT ON
) turns off all the other standards.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
OFF
Example:
BB:DM:STAT ON
switches digital modulation on.
[:SOURce<hw>]:BB:DM:SWITching:SOURce
<Source>
The command selects the source of the CW control signal for switching between a modu-
lated and an unmodulated signal.
Parameters:
<Source>
INTernal
INTernal
The CW signal in the control list is used for the control.
*RST:
INTernal
Example:
BB:DM:SWIT INT
the CW signal in the control list is used for the control.
[:SOURce<hw>]:BB:DM:SWITching:STATe
<State>
The command enables switching between a modulated and an unmodulated signal.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:DM:SWIT:STAT INT
CW switching is active.
Clock Settings
............................................................................552
......................................................................553
........................................................................553
..................................................553
...............................................554
[:SOURce<hw>]:BB:DM:CLOCk:MODE
<Mode>
The command enters the type of externally supplied clock (
:BB:DM:CLOCk:SOURce
EXTernal
).
Parameters:
<Mode>
SYMBol | MSYMbol
*RST:
SYMBol
SOURce Subsystem
Содержание SMBV100A
Страница 31: ......
Страница 117: ...Manual Operation R S SMBV100A 100 Operating Manual 1407 6062 32 08 Legend of Front Panel Controls ...