Remote Control Commands
R&S
®
SMBV100A
652
Operating Manual 1407.6062.32 ─ 08
The command corresponds to the manual-control
Execute Single Sweep - LF Sweep
Example:
LFO:SWE:MODE SING
sets the single cycle mode of the LF sweep.
LFO:SWE:EXEC
starts one cycle of the LF sweep.
Usage:
Event
[:SOURce]:LFOutput:SWEep[:FREQuency]:MODE
<Mode>
The command sets the cycle mode of the LF sweep.
The assignment of the GPIB commands to the sweep modes is given in the description
of the sweep menus.
Parameters:
<Mode>
AUTO | MANual | STEP
AUTO
Each trigger triggers exactly one complete sweep.
MANual
The trigger system is not active. Each frequency step of the sweep
is triggered individually, either by varying the "Current Fre-
quency" value using the rotary knob under manual control or by
means of a
:LFOutput:FREQ:MAN
command under remote con-
trol.
With manual control, the frequency increases or decreases
(depending on the direction of the rotary encoder) by the value
specified under
SOUR:LFO:SWE:FREQ:STEP:LIN
(linear spac-
ing) or
...:STEP:LOG
(logarithmic spacing).
With remote control, the frequency increases by the value speci-
fied under
LFO:SWE:FREQ:STEP:LIN|LOG
which each sent
spective the value entered there.
STEP
Each trigger triggers one sweep step only. The frequency increa-
ses by the value entered under
[SOURce:]LFOutput:SWEep:STEP
.
*RST:
AUTO
Example:
LFO:SWE:MODE AUTO
selects Mode Auto.
[:SOURce]:LFOutput:SWEep[:FREQuency]:POINts
<Points>
The command sets the number of steps in an LF sweep.
The command is linked to the command
:LFOutput:SWEep[:FREQuency]:STEP
as
follows:
●
for linear sweeps and
STARt < STOP
SOURce Subsystem