Instrument Function
R&S
®
SMBV100A
232
Operating Manual 1407.6062.32 ─ 08
"Insert Range"
Inserts new rows before the marked row. The number of rows to be
inserted can be defined in an entry window.
"Fill...."
Opens a sub menu for defining a set of list values to be automatically
entered in the List Mode table (see
chapter 5.4.15.2, "Filling the List
"Delete Row"
Deletes the marked row.
"Delete
Range..."
Allows to delete any number of rows starting with the marked row. The
number of rows to be deleted can be defined in an entry window.
"Save as"
Open the file menu to save the list under a new name.
Each list is saved to the instrument's hard disk as a separate file with
the file prefix
*.lsw
. The file name and the directory to which the file
is saved are user-selectable.
"Save"
The list is saved under its current name.
List Range In - List Mode
Defines an index range in the current list by setting the start and stop index. Only the
values in the selected index range are processed in List mode, all other list entries are
ignored.
SCPI command:
Trigger Input Slope
Sets the polarity of the active slope of an applied instrument trigger.
This setting affects the INST TRIG input (BNC connector at the rear of the instrument).
"Positive"
The rising edge of the trigger signal is active.
"Negative"
The falling edge of the trigger signal is active.
SCPI command:
Import/Export
Lists can be imported from externally created files or exported into text or CSV-files. The
import/export settings are available after clicking the "Import/Export" button.
Import/Export - List Mode
Expands the menu with the area for import and export of list mode files.