P109
DC brake current
S
P
Setting range
0 … 250 %
Factory setting
{ 100 }
Description
Current setting for the functions of DC current braking (
P108 = 3
) and combined
braking (
P108 = 5
).
The correct setting value depends on the mechanical load and the required
deceleration time. A higher setting brings large loads to a standstill more quickly.
The 100 % setting corresponds to a current value as stored in the "Nominal motor
current" parameter
P203
.
Note
The DC current (0 Hz) which the FI can supply is limited. For this value, please refer
to the table in Section "Reduced overcurrent due to output frequency", column: 0 Hz.
In the basic setting this limiting value is 110 %.
DC Braking: Not for PMSM motors!
P110
Time DC-brake on
S
P
Setting range
0.00 … 60.00 s
Factory setting
{ 2.00 }
Description
The time for which the DC current selected in
P109
is applied to the motor. For this,
function {3}
“Instant d.c. Braking””
must be set in
P108
.
Depending on the relationship of the actual output frequency to the max. frequency
P105
, the "DC brake time" is shortened.
The time starts running with the removal of the enable and can be interrupted by
renewed enabling.
Note
DC Braking: Not for PMSM motors!
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...