P549
Pot Box function
S
Setting range
0 … 16
Factory setting
{ 0 }
Description
This parameter provides the option of adding a correction value (fixed frequency,
analogue value, bus) to the actual setpoint value by means of the ControlBox
keyboard. An explanation can be found in the description of
P400
.
Setting values
Value
Meaning
Value
Meaning
0
Off
4
Frequency addition
5
Freq. subtraction
P550
μSD orders
Setting range
0 … 10
Factory setting
{ 0 }
Scope of application
SK 530P, SK 550P
Description
If a Micro SD card is present in slot X18, entire parameter sets (each consisting of the
parameter sets 1 – 4) can be exchanged between the microSD card and the
frequency inverter.
Note:
This does not include Ethernet-related parameters.
Note
5 storage areas are available on the microSD card. Therefore data sets from a total of
5 different frequency inverters can be archived on the card.
NB:
Do not remove the microSD card during data transfer (loss of data! + Error
E026
)
NOTICE!
The existing data will be overwritten.
NOTICE!
The data to be copied are not checked for plausibility. When writing to the
frequency inverter, take care that the correct data set for the FI is transferred,
otherwise frequency inverter malfunctions may occur.
Setting values
Value
Meaning
0
No change
No copying
1
FI
μSD 1
The data set is copied from the frequency inverter to storage area 1
of the microSD card.
2
FI
μSD 2
As for 1, however to storage area 2.
3
FI
μSD 3
As for 1, however to storage area 3.
4
FI
μSD 4
As for 1, however to storage area 4.
5
FI
μSD 5
As for 1, however to storage area 5.
6
μSD 1
FI
The data set is copied from storage area 1 of the microSD card to
the frequency inverter.
7
μSD 2
FI
As for 6, however to storage area 2.
8
μSD 3
FI
As for 6, however to storage area 3.
9
μSD 4
FI
As for 6, however to storage area 4.
10
μSD 5
FI
As for 6, however to storage area 5.
11
Format μSD
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...