2.1 Frequency inverter installation
Install the frequency inverter directly on the rear wall of a control cabinet. Sizes 1 and 2 have two
mounting holes, size 3 has four mounting holes.
Care must be taken that the rear of the cooling element is covered with a flat surface and that the
inverter is mounted vertically. This enables optimum convection, which ensures fault-free operation.
Power
[kW]
Device type
SK 5xxP-…
Si
ze
Overall dimensions
(as delivered)
Fixing dimensions
(Wall mounting)
We
ig
h
t a
p
p
ro
x
. [
k
g
]
2)
A
B
C
D
E1
E2
∅
H
ei
g
ht
W
idt
h
D
ept
h
H
ol
e s
pac
ing
len
gt
h
H
ol
e s
pac
ing
wid
th
H
ol
e s
pac
ing
edg
e
D
iam
et
er
From
to
From
to
0.25
0.75
250-123 750-123
1
200
66
141
180
22
–
5.5
1.2
250-340 750-340
1.1
2.2
111-123 221-123
2
240
1)
66
141
220
22
–
5.5
1.6
111-340 221-340
3.0
5.5
301-340 551-340
3
286
91
175
220
22
–
5.5
2.6
All dimensions in mm
1) SK 5xxP-221-123: Mains connection terminal protrudes approx. 15 mm beyond the stated
overall dimension H .
2) depending on configuration
Information
Frequency inverters with configuration versions SK 530P and higher can be extended with a plug-in
option module. This increases the installation depth by 23 mm.
Sizes 1 and 2
Size 3
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...