5 Parameter
BU 0600 en-3221
89
Information
If the mains voltage is not connected (X1) the following parameter shows the value 0 and not the
actual correct operating value.
P034
60FD Actual dig. in.
S
Display range
-2147483648 … 2147483647
Factory setting
{ 0 }
PDO mapping
TxPDO
Data type
UNSIGNED 32 Bit
Description
DS402 object 60FDh: Displays the actual status of the digital inputs.
Setting values
Value
Function
Description
Bit: 0
Negative limit switch
Negative limit switch
Bit: 1
Positive limit switch
Positive limit switch
Bit: 2
Home switch
Reference switch
Bit: 3
… 15: reserved
Bit: 16
Bus/ 2nd IOE Dig In1
Bit: 17
Digital input 2 (DI2)
Bit: 18
Digital input 3 (DI3)
Bit: 19
Digital input 4 (DI4)
Bit: 20
Digital input 5 (DI5)
Bit: 21
Digital input 6 (DI6)
Bit: 22
Digital input 7 (DI7)
Bit: 23
Digital input 8 (DI8)
Bit: 24
Digital input 9 (DI9)
Bit: 25
Digital input 10 (DI10)
Bit: 26
Digital input 11 (DI11)
Bit: 27
Digital input 12 (DI12)
Bit: 28
Digital function, analogue input 1 (AI1)
Bit: 29
Digital function, analogue input 2 (AI2)
Information
If the mains voltage is not connected (X1) the following parameter shows the value 0 and not the
actual correct operating value.
P035
60FE Digital output
S
Setting range
-2147483648 … 2147483647
Factory setting
{ 0 }
PDO mapping
RxPDO
Data type
UNSIGNED 32 Bit
Description
DS402 object 60FEh: The digital outputs of the frequency inverter can be set with this
object.
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...