NORDAC
PRO
(SK 500P) – Manual with installation instructions
68
BU 0600 en-3221
3~ Mot
IEC 56
IM B3
cos
j
0.74
cosj 0.74
IP55
Red Terminal 16 Th.Cl.F
EN60034
60 Hz
460 V Y
5.2 A
2.5 kW
1765 rpm
1440 rpm
P206
P201
P204
P203 P202
P200
9.0 /
5.2 A
50 Hz
2.2 kW
P207
P200 Motor list:
0 = No change
8 = 0.37kW 400V
1 = No motor
9 = 0.50PS 460V
2 = 0.25kW 230V
10 = 0.55kW 230V
3 = 0.33PS 230V
11 = 0.75PS 230V
4 = 0.25kW 400V
12 = 0.55kW 400V
5 = 0.33PS 460V
13 = 0.75PS 460V
6 = 0.37kW 230V
14 = 0.75kW 230V
7 = 0.50PS 230V ....
230 /
400 V
D/
Y
Figure 6: Motor type plate
RECOMMENDATION:
For correct operation of the drive unit, it is necessary to input the motor
data (name plate) as precisely as possible. In particular, automatic stator
resistance measurement using parameter
P220
is recommended.
To automatically determine the stator resistance,
P220 = 1
must be set
and confirmed by pressing "ENTER". The value calculated for the line
resistance (depending on
P207
) will be saved in
P208
.
Motor data for IE1 / IE2 motors are provided via the NORDCON software. With the aid of the "Import
motor parameter" function (also refer to the NORDCON software manual
), the required data
set can be selected and imported into the frequency inverter.
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...