NORDAC
PRO
(SK 500P) – Manual with installation instructions
148
BU 0600 en-3221
P436
Dig. out. hysteresis
S
P
Setting range
1 … 100 %
Arrays
[-01] = Binary output.1 / MFR1 Multi-function relay 1 (K1) integrated into the FI
[-02] = Binary output.2 / MFR2 Multi-function relay 2 (K2) integrated into the FI
[-03] = Digital output 1
Digital output 1 (DO1) integrated into the FI
[-04] = Digital output 2
Digital output 2 (DO2) integrated into the FI
[-05] = Digital output 3
Digital output 3 (DO3) integrated into SK CU5
[-06] = Digital output 4
Digital output 4 (DO4) integrated into SK CU5
[-07] = Digital output 5
Digital output 5 (DO5) integrated into SK CU5
[-08] = Digital output 6
Digital output 6 (DO6) integrated into SK CU5
[-09] = Digital function Analog1 Digital output 1 (AO1) (digital function) integrated
into the FI
[-10] = Reserve
Scope of application
[-01] … [-02]
SK 500P and higher
[-03] … [-08]
SK 530P and higher
[-09] … [-10]
SK 500P and higher
Factory setting
All { 10 }
Description
"Digital output hysteresis"
Difference between switch-on and switch-off point to
prevent oscillation of the output signal.
P460
Watchdog time
S
Setting range
-250.0 ... 250.0 s
Factory setting
{ 10.0 }
Setting values
Value
Meaning
0.1 ... 250.0
The time interval between the expected watchdog signals (programmable function of the
digital inputs
P420
). If this time interval elapses without an impulse being registered, switch-
off and error message
E012
are actuated.
0.0
Customer error:
As soon as a High-Low flank or a Low signal is registered on a digital input
(Function 18), the FI switches off with error message
E012
.
-0.1 … -250.0
Rotor run watchdog:
In this setting the rotor run watchdog is active. The time is defined by
the set value. There is no watchdog message when the FI is switched off. After each enable,
a pulse must first come before the watchdog is activated.
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...