6 Operating status messages
BU 0600 en-3221
203
The LED labelled
"BUS"
indicates the status of communication at the system bus level.
Status
Meaning
Off
•
No process data communication
Lights up green
•
Process data communication active
Flashing green (4 Hz)
•
Bus warning
Flashing red (4 Hz)
•
Monitoring error P120 or P513 ( E10.0/E10.9)
Flashing red (1 Hz)
•
Field bus interface telegram timeout (E10.2/E10.3)
Lights up red
•
System bus in state “Bus off”
The LED labelled
"USB"
indicates the status of the USB connection.
Status
Meaning
Orange off
•
USB driver in PC not correctly initialised
Orange lights up
•
USB connection active
Lights up red
•
USB connection error
ControlBox Display
The ControlBox displays an error with its number and the prefix "E". In addition, the present fault can
be displayed in array element [
-01
] of parameter (
P700)
. The last error messages are stored in
parameter (
P701
). Further information about the frequency inverter status at the moment of the fault
can be obtained from parameters (
P702
) to (
P706
) / (
P799
)
If the cause of the error is no longer present, the error display in the ControlBox flashes and the error
can be acknowledged with the Enter key.
In contrast, warning messages are prefixed with "C" ("
Cxxx
") and cannot be acknowledged. They
disappear automatically when the reason for them is no longer present or the frequency inverter has
switched to the "Error" state. Display of the message is suppressed if the warning appears during
parameterisation.
The present warning message can be displayed in detail at any time in array element [
-02
] of
parameter (
P700
).
The reason for an existing disabled switch on cannot be displayed with the ControlBox.
ParameterBox display
The ParameterBox displays the messages in plain text.
Control panel
The following options are available:
• Mounted control panel with 7-Segment display (ControlBox SK TU5-CTR)
• Cable-connected control panel with 7-Segment display (SimpleControlBox SK CSX-3E and
SK CSX-3H)
• Cable-connected control panel with plain text display (ParameterBox SK PAR-3E and SK PAR-3H)
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...