3-67
Operating the monitor screen
3Explanation of operation methods
7) Press the function key corresponding to "Close" in monitor menu screen is pressed, finish the monitor, and
return to the original screen.
(3) Input register monitor
If CC-Link is used, it is the function which always monitors the value of the input register.
Note) Since there is no CC-Link option in the CRnQ-700 series, this function can not be used.
1) Press the [3] key in the monitor menu screen, and display the input register screen. The input register of
the 4 registers can be monitored on the one screen.
The case where the state of the input register 8000 is confirmed is shown in the following.
2) Press the function key corresponding to "Number".
3) Set "8000" as the start number.
4) Display the ON/OFF state of the 4 input register at the head for the input register No. 8000.
Press the function key corresponding to "Next", then display the next input register screen. Press the function
key corresponding to "Prev", then display the previous input register screen.
<MONITOR>
1.INPUT
2.OUTPUT
3.INPUT REG. 4.OUTPUT REG.
5.VARIABLE 6.ERROR LOG
CLOSE
123
<FILE/EDIT> 1/20 Rem 136320
1 08-04-24 17:20:32 22490
2 08-04-24 14:56:08 694
A1 08-04-24 13:05:54 2208
B1 08-04-24 13:05:54 1851
COPY
123
POSI.
EDIT
NEW
⇒
<INPUT REGISTER>
6000 0 0×0000
6001 0 0×0000
6002 0 0×0000
6003 0 0×0000
CLOSE
123
NUMBER
Prev
Next
<MONITOR>
1.INPUT 2.OUTPUT
3.INPUT REG.
4.OUTPUT REG.
5.VARIABLE 6.ERROR LOG
CLOSE
123
<INPUT REGISTER>
6000 0 0×0000
6001 0 0×0000
6002 0 0×0000
6003 0 0×0000
CLOSE
123
NUMBER
Prev
Next
<INPUT REGISTER>
START No. (_ )
CLOSE
123
<INPUT REGISTER>
8000 0 0×0000
8001 0 0×0000
8002 0 0×0000
8003 0 0×0000
CLOSE
123
NUMBER
Prev
Next
<INPUT REGISTER>
8004 0 0×0000
8005 0 0×0000
8006 0 0×0000
8007 0 0×0000
CLOSE
123
NUMBER
Prev
Next
Next
[F3]
Previous [F2]