5Functions set with parameters
Signal parameter
5-352
Output signal
reset pattern
Refer to
"5.14About the
output signal
reset pattern"
Set the operation to be taken when the general-purpose output signal
for the Clr command or dedicated input (OUTRESET) is reset. Sig-
nals are output in the pattern set here even when the power is turned
ON.
Set with a 32-bit unit for each signal using the following parame-
ters.(OFF/ON/hold=0/1/*)
ORST0
Character
string 4
Set the signal No. 0 to 31.
00000000,00000
000,00000000,00
000000
ORST32
:
ORST8016
Character
string 4
Set the signal No. 32 to 63.
:
Set the signal No. 8016 to 8047
00000000,00000
000,00000000,00
000000
:
Output reset at
reset
SLRSTIO
Integer 1
Designate the function to carry out general-purpose output signal
reset when the program is reset.
(Invalid/Valid=0/1)
0(Invalid)
Multi CPU
quantity setting
(CRnQ-700
only)
QMLTCPUN
Integer 1
At the multi CPU system, set the number of CPU units with which the
standard base unit is equipped.
2
Multi CPUn
high-speed
communication
area setting
(CRnQ-700
only)
QMLTCPUn
n=1 ~ 4
Integer
4
At the multi CPU system, set the number of points performing
transmission and receipt between each CPU unit for the high speed
communication function between multi CPU nos. 1 to 4.
It is necessary to match the parameter settings for all CPUs. An error will
occur at the sequencer CPU If the parameter settings do not match, and
therefore care should be taken to ensure that the parameter settings for
each CPU match.
First element: User free area size (k points)
Range: 1 to 14 (Max. *) * The max. value will differ based on the number
of multi CPUs as shown below.
Second element: No. of auto refresh points (points)
Range: 0 to 14335
The robot CPU does not support auto refresh, and therefore the
number of points for auto refresh should always be set to 0.
Third element: System area size (K points)
Range: 1 or 2
Fourth element: Multi CPU synchronous start-up (1: Yes, 2: No)
Robot CPUs take some time to start up and therefore the current
setting of 1 (synchronous start-up) should not be changed.
1,0,1,1
Parameter
Parameter
name
No. of arrays
No. of characters
Details explanation
Factory setting
CPU Qty
Setting Range
2
0 ~ 14K
points
3
0 ~ 13K
points
4
0 ~ 12K
points