5Functions set with parameters
About ROM operation/high-speed RAM operation function
5-388
[2] Execute a restore operation by manipulating the operation panel
[3] Change the parameter value and switch to the RAM operation.
Change the value of the ROMDRV parameter from 1 to 0.
After changing it, be sure to shut off the power, and turn it on
again.
START
STATUS NUMBER
STATUS NUMBER
STATUS NUMBER
STATUS NUMBER
STATUS NUMBER
STATUS NUMBER
Power ON
Approx. 8 sec.
Approx. 12 sec.
Approx. 8 sec.
STATUS NUMBER
Power ON
The com pletion of restoring into the RAM area
is displayed.
This display varies depending on whether or
not there is extension m em ory.
OK4: W hen standard m em ory is used
OK7: W hen 2 MB extension m em ory is used
* The tim e required to start up after the power
is turned on is alm ost the sam e as the norm al
operation, which is different from when writing
to the ROM area.
Approx. 12 sec.
Press the [START] button on the operation panel.
"88888" is displayed in STATUS NUMBER just like
for norm al operation.
Power O N at
norm al operation
Power O N after a write
restoring into the RO M area
<PARAMETER> NAME(ROMDRV )
ELE( )
DATA
(0 )
CLOSE
123
Next
DATA
Prev
<PARAMETER> NAME(ROMDRV )
ELE( )
DATA
(1 )
CLOSE
123
Next
DATA
Prev