5Functions set with parameters
Operation parameter
5-356
5.3 Operation parameter
These parameters set the items pertaining to the operations of the controller, T/B and so forth.
Table 5-5:List Operation parameter
Parameter
Parameter
name
No. of arrays
No. of characters
Details explanation
Factory setting
Buzzer ON/
OFF
BZR
Integer 1
Specifies the on/off of the buzzer sound that can be heard when an
error occurs in the robot controller.
(OFF/ON=0/ÇP)
1(ON)
Program reset
operation rights
PRSTENA
Integer 1
Whether or not the operation right is required for program reset
operation
(Required/Not required = 0/1)
If operation rights are abandoned, program can be reset from any-
where. However, this is not possible under the teaching mode for
safety reasons.
0(Required)
Program reset
when key
switch is
switched
MDRST
Integer 1
Program paused status is canceled when the key switch is oper-
ated.
(Invalid/Valid=0/1)
0(Invalid)
Operation panel
display mode .
OPDISP
Integer 1
Setting of the 5-digit LED display when the key switch is changed
over
0: Override display takes effect when the key switch is changed
over (initial value).
1: The current display mode is maintained even after the key switch
is changed over.
0 (
Override
display
)
Program selec-
tion rights set-
ting
OPPSL
Integer 1
Specifies the program selection operation rights when the key
switch of the operation panel is in AUTO (OP) mode.
(External/OP=0/1)
1(OP)
RMTPSL
Integer 1
Designate the program selection operation rights for the automatic
(Ext) mode.
(External/OP=0/1)
0(External)
TB override
operation rights
OVRDTB
Integer 1
Specifies whether the operation rights are required when changing
override from T/B.
(Not required/Required = 0/1)
1(Required)
Speed setting
during mode
change
OVRDMD
Integer 2
Override is set automatically when the mode is changed.
First element..........override value when the mode is automatically
changed from teaching mode
Second element.....Override value when the mode is changed from
Auto to Teaching.
Current status is maintained if changed to 0.
0,0
Override
change opera-
tion rights
OVRDENA
Integer 1
Specifies whether the operation rights are required when changing
override from the operation panel and external device.
(Not required/Required = 0/1)
1(Required)
This parameter
switches the
access target of
a program.
Refer to
380, "5.18
About ROM
operation/high-
speed RAM
operation func-
tion"
ROMDRV
Integer 1
The access target of a program can be switched between RAM and
ROM.
0: RAM mode. (Standard mode.)
1: ROM mode. (Special mode.)
2: High-speed RAM mode
0 (RAM mode.)
Copy the infor-
mation on the
RAM to the
ROM
Refer to
380, "5.18
About ROM
operation/high-
speed RAM
operation func-
tion"
BACKUP
Character
string 1
Copy the program, the parameter, the common variable, and the
error log to the ROM from the RAM.
Do not change this parameter.
SRAM->FLROM
(unchangeable)