3-49
Automatic operation
3Explanation of operation methods
(6) Resetting the program
The program's stopped state is canceled, and the execution line is returned to the head.
*Operating with the controller
1) Set the T/B [ENABLE] switch to "DISABLE".
2) Set the controller [MODE] switch to "AUTO-
MATIC".
3) Press the controller [CHG DISP] switch, and
display the program No.
4) Press the controller [RESET] switch.
The STOP lamp will turn OFF, and the pro-
gram's stopped state will be canceled.
*Operating with the T/B
1) Set the [Mode selection switch] on the front of
the controller to "MANUAL".
2) Set the T/B [ENABLE] switch to "ENABLE".
3) Press the [EXE] key while holding down the
[RESET] key. The execution line will return to
the head, and the program will be reset.
RESET
CHNG DISP
Reset
T/B disable
Controller enable
Execute of program reset
Display the program No.
MODE
MANUAL
AUTOMATIC
Down:
ENABLE
*Lighting
Up :
DISABLE
Rear of T/B
Program reset [RESET] + [EXE]
Execute of program reset
T/B enable
Controller disable
Down:
ENABLE
*Lighting
Up :
DISABLE
Rear of T/B
MODE
MANUAL
AUTOMATIC
Valid only while program is stopped
The program cannot be reset while the program is running. Always carry out this step while the program is
stopped.
When resetting the program from the controller operation panel, display the "program No." on the STA-
TUS NUMBER display, and then reset.
STOP lamp turns OFF
The STOP lamp will turn OFF when the program is reset.