MDS-E/EH Series Instruction Manual
9 Power Backup System
462
IB-1501229-F
9.4.6 Trouble Shooting at Power ON
If the drive unit does not start up correctly and a system error occurs when the drive unit power is turned ON, the power
backup unit may not have been started up properly. Check the LED display on the power backup unit, and take
measures according to this list.
LED
display
Symptom
Cause of occurrence
Investigation method
Remedy
None
PFU unit fails to start.
PFU's internal fuse is
open.
Check whether the power voltage is
properly input to L1, L2 and L3.
If voltage is properly input, replace
the power backup unit.
b
Unable to cancel emergency stop.
External emergency stop is occurring
on the power supply unit. (The LED on
power supply unit shows "q".
)
Disconnection of the DO3
signal of CN43.
Check if the DO3 signal of CN43 is
correctly connected to CN23A of the
power supply unit.
Connect correctly.
Check if the 24V power supply of
DO3 signal is correctly connected to
DO_COM terminal.
Connect correctly.
1A
Unable to cancel emergency stop.
External emergency stop is occurring
on the power supply unit. (The LED on
power supply unit shows "q".
)
Disconnection of the
resistor unit or an illegal
resistance value.
Check the investigation items of the alarm No. 1A.
PFU's internal resistor
regeneration transistor is
broken.
Unplug L+/L-, C+/C- and R1/R2
from the PFU unit, and measure the
resistance between L+/L- terminals.
If short-circuited, replace the power
backup unit.
51
Unable to cancel emergency stop. The
alarm 6C (Power supply: Main circuit
error) is occurring.
PFU's internal resistor
regeneration transistor is
broken.
Unplug L+/L-, C+/C- and R1/R2
from the PFU unit, and measure the
resistance between L+/L- terminals.
If short-circuited, replace the power
backup unit.
52
Power supply or drive unit fails to start.
An error in the control
power output circuit.
Check the investigation items of the alarm No. 52.
d1
Unable to cancel emergency stop.
External emergency stop is occurring
on the power supply unit. (The LED on
power supply unit shows "q".
)
Over-regeneration
protection is working.
Check the investigation items of the warning No. D1.
d5
Unable to cancel emergency stop.
External emergency stop is occurring
on the power supply unit. (The LED on
power supply unit shows "q".
)
An overheat was detected
by the thermal sensor of
the resistor unit.
Check the investigation items of the warning No. D5.
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......