MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
346
IB-1501229-F
(4) Adjustment procedures
The adjustment procedures of high-speed synchronous tapping function are shown below.
CAUTION
1. Perform the high-speed synchronous tapping function adjustment after servo adjustment.
2. Use NC Analyzer2 to check the synchronous tapping waveforms. The displayed value of the load meter is the torque
current command.
3. Make sure to change the load display (SP228 bit0 to 2) back to the initial setting value and disable the machine error
compensation amount (SV113 bit7=0) after high-speed synchronous tapping adjustment. Failure to observe this causes
initial parameter error alarm 37 to occur after turning the NC power supply ON again.
YES
Synchronous tapping
waveform check
Synchronous error waveform within judgement value?
No speed overshooting at stop?
No vibration of torque current command
at stop?
Finish
#3017 (tapt1) to #3020 (tapt4)
Tapping time constant
Measured acceleration/deceleration time × 1.2
Disable machine error compensation amount
Set "1" to SV113/bit7
#3013 (stap1) to #3016 (stap4)
Measure acceleration/deceleration time of
maximum tapping rotation speed.
Parameter/Time constant
adjustment
Enable Machine error compensation amount
Set "0" to SV113 bit7
SP228 bit0 to 2: Load display
Set to "000" (normal setting)
#3120 (staptr) Time constant reduction rate in
high-speed synchronous tapping Set to "0"
Enable high-speed synchronous tapping
SP226/bit3=1
(Note 2)
(Note 3)
NO
SP228 bit0 to 2: Load display
Set to "110" (Torque current command display)
Set a value of about 1.1 times of the time constant
where a speed overshoot or a current vibration does
not occur at stop.
The displayed value of the load meter becomes the torque current
command value by setting the parameter.
Setting for checking synchronous error during adjustment
Disabled during adjustment because backlash and pitch error change the
synchronous error waveforms.
SV129: Synchronous control feed forward filter frequency
SV244: Communication interpolation unit for
communication among drive units
[
Spindle
]
SP244: Communication interpolation unit for
communication among drive units
#
High-speed synchronous tapping-related parameter settings
[
NC
]
1281/bit5: High-speed synchronous tapping enabled
[
Servo
]
SV032: Torque offset
SV037: Load inertia scale
Start
Check that the parameters related to high-speed
synchronous tapping function are set.
(Note 1)
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......