MDS-E/EH Series Instruction Manual
7 Troubleshooting
377
IB-1501229-F
(Note 1) Definitions of terms in the table are as follows.
Main side encoder: Encoder connected to CN2
Sub side encoder: Encoder connected to CN3
(Note 2) Resetting methods
NR: Reset with the NC RESET button. This alarm can also be reset with the PR and AR resetting conditions.
PR: Reset by turning the NC power ON again. This alarm can also be reset with the AR resetting conditions.
When the control axis is removed, this alarm can be reset with the NC RESET button. (Excluding alarms 32 and 37.)
AR: Reset by turning the NC and servo drive unit power ON again.
No.
Name
Details
Reset
method
Servo
stop method
Spindle
stop method
27 Sub side encoder: Error 5
An error was detected by the encoder connected to the machine side.
The error details are different according to the encoder type.
Refer to "Encoder alarm" for details.
Dynamic stop Coast to a stop
28 Sub side encoder: Error 6
29 Sub side encoder: Error 7
2A Sub side encoder: Error 8
2B Main side encoder: Error 1 An error was detected by the encoder connected to the motor side.
The error details are different according to the encoder type.
Refer to "Encoder alarm" for details.
Dynamic stop Coast to a stop
2C Main side encoder: Error 2
2D Main side encoder: Error 3
2E Main side encoder: Error 4
2F Main side encoder:
Communication error
An error was detected in the communication with the motor side
encoder.
PR
Dynamic stop Coast to a stop
30 Over regeneration
Over-regeneration level exceeded 100%. The regenerative re-
sistor is overloaded.
PR
Dynamic stop Coast to a stop
31 Overspeed
The motor speed exceeded the allowable speed.
PR
Deceleration
stop
Deceleration
stop
32 Power module error
(overcurrent)
The power module detected the overcurrent.
PR
Dynamic stop Coast to a stop
33 Overvoltage
The bus voltage in main circuit exceeded the allowable value.
PR
Dynamic stop Coast to a stop
34 NC communication:
CRC error
The data received from the NC was outside the setting range.
PR
Deceleration
stop
Deceleration
stop
35 NC command error
The travel command data received from the NC was excessive.
PR
Deceleration
stop
Deceleration
stop
36 NC communication:
Communication error
The communication with the NC was interrupted.
PR
Deceleration
stop
Deceleration
stop
37 Initial parameter error
An incorrect set value was detected among the parameters
send from the NC at the power ON.
In the SLS(Safely Limited Speed) function, an error was detect-
ed in the relation between the safety speed and safety rotation
number in the speed observation mode.
PR
Initial error
Initial error
38 NC communication:
Protocol error 1
An error was detected in the communication frames received
from the NC.
Or, removing an axis or changing an axis was performed in the
synchronous control.
PR
Deceleration
stop
Deceleration
stop
39 NC communication:
Protocol error 2
An error was detected in the axis data received from the NC.
Or, in changing an axis, the parameter setting of the synchro-
nous control was applied when the axis was installed.
PR
Deceleration
stop
Deceleration
stop
3A Overcurrent
Excessive motor drive current was detected.
PR
Dynamic stop Coast to a stop
3B Power module error
(overheat)
The power module detected an overheat.
PR
Dynamic stop Coast to a stop
3C Regeneration circuit error
An error was detected in the regenerative transistor or in the re-
generative resistor.
PR
Dynamic stop
-
3D Power supply voltage error
at acceleration/deceleration
A motor control error during acceleration/deceleration, due to a
power voltage failure, was detected.
PR
Dynamic stop
-
3E Magnetic pole position de-
tection error
The magnetic pole position, detected in the magnetic pole posi-
tion detection control, is not correctly detected.
AR
Dynamic stop Coast to a stop
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......