(4) Control during the servo OFF command
When a servo OFF command is input by an NC sequence input, the motor brake turns ON simultaneously when the
motor ON is shut off. Note that the vertical axis drop prevention control is not validated, so a drop due to the brake
operation lag occurs. When the servo OFF is canceled, a drop due to an uncontrolled state does not occur.
(5) Operation sequences when an emergency stop occurs
The motor brake control output operation when an emergency stop occurs differs according to the motor
deceleration stop method. Refer to section "Setting for emergency stop" for details on the operation sequences for
each stop method.
POINT
Using the high-speed ready ON sequence, set the parameter for all the axes including the spindle. Especially when it is not
set for the power supply control axis, power supply will not work at high-speed sequence.
CAUTION
When SV017/bit2=1, SP017/bit2=1 is set, for the model using an external dynamic brake, the Ready completion will be
delayed by 10ms to ensure the external contactor operation time.
CAUTION
1. The vertical axis drop prevention control only is performed during an emergency stop (including alarms and power
failures). It is not performed when a servo OFF command is input.
2. To operate the motor brake control output (MBR) of the 2-axis or 3-axis drive unit, input the servo OFF command to all
the servo axes in the unit.
Servo OFF command
Dynamic brake
Motor brake control output (CN20)
Motor ON (GATE)
Motor brake control sequences when a servo OFF command is output
SERVO ON
SERVO OFF
OFF
ON
ON
OFF
OFF
ON
200ms
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......