bit 5-4 : dfhz Notch filter frequency range
Set the adaptive range of the notch filter frequency. When the adaptive follow-up function is enabled and if
the estimated resonance frequency exists in the set range, the notch filter will be adapted. Normally set this
parameter to "00".
bit5,4=
00: -10 to 10 [%]
01: -20 to 20 [%]
10: -30 to 30 [%]
11: -40 to 40 [%]
bit 3-0 : esn Sensitivity of estimated resonance frequency
Set the sensitivity of the estimated resonance frequency. Smaller setting value enables to detect smaller vi-
bration component, however, adaptive movement will be repeated frequently. Normally set this parameter to
"0".
0 : Normal setting (same sensitivity as A) 1 : Sensitivity high to F : Sensitivity low
bit1: fctcfw Full-closed torsion compensation function forward direction compensation enabled
Compensate the torsion amount in the forward direction with the full-closed torsion compensation function.
When compensating the torsion amount in the reverse direction only, set to "0".
0: Stop 1: Start
For high-accuracy binary resolution encoder, set the number of pulses to four bite data of SV117 (high-order)
and SV019 (low-order) by pulse (p).
When SV117=0, the setting unit of SV019 is (kp).
Refer to SV019 for details.
Related parameters: SV019, SV020, SV118
---Setting range---
-1 to 32767
When using high-accuracy binary resolution encoder, set the number of pulses to four bite data of SV118
(high-order) and SV020 (low-order) by pulse (p).
When SV118=0, the setting unit of SV020 is (kp).
Refer to SV020 for details.
Related parameters: SV019, SV020, SV117
---Setting range---
-1 to 32767
Not used. Set to "0".
Set the acceleration rate feed forward filter frequency in high-speed synchronous tapping control. The stan-
dard setting is "600".
Related parameters: SV244
---Setting range---
0 to 32767 (rad/s)
#2316
SV116 SSF11
Servo function 11
(PR)
#2317
SV117 RNG1ex
Expansion sub side encoder resolution
(PR)
#2318
SV118 RNG2ex
Expansion main side encoder resolution
#2319-2328
SV119 - SV128
#2329
SV129 Kwf
Synchronous control feed forward filter frequency
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......