MDS-E/EH Series Instruction Manual
14 Appx. 5: EMC Installation Guidelines
498
IB-1501229-F
14.1 Introduction
As the NC unit is a component designed to control machine tools, it is believed to be out of the direct EMC Instruction subject.
However, we would like to introduce the following measure plans to backup EMC Instruction compliance of the machine tool
as the NC unit is a major component of the machine tools.
[1] Methods for installation in control/operation panel
[2] Methods of wiring cable outside of panel
[3] Introduction of countermeasure parts
Mitsubishi is carrying out tests to confirm the compliance to the EMC Standards under the environment described in this
manual. However, the level of the noise will differ according to the equipment type and layout, control panel structure and
wiring lead-in, etc. Thus, we ask that the final noise level be confirmed by the machine tool builder.
For measures for CNC, refer to "EMC INSTALLATION GUIDELINES" of each NC Connection Manual.
14.2 EMC Instructions
The EMC Instructions regulate mainly the following two withstand levels.
Emission ..... Capacity to prevent output of obstructive noise that adversely affects external sources.
Immunity ..... Capacity not to malfunction due to obstructive noise from external sources.
The details of each level are classified in the table below. It is assumed that the Standards and test details required for a
machine tool are about the same as these.
Class
Name
Details
Generic
Standard
Standards for
determining test
and measurement
Emission
Radiated noise
Electromagnetic noise radiated through the air
EN61000-6-4
(General
industrial
machine)
EN61800-3
(Motor
control unit)
-----
Conductive noise
Electromagnetic noise discharged from power
line
Immunity
Static electricity electrical
discharge immunity test
(Example) Withstand level of discharge of
electricity charged in a human body.
EN61000-6-2
(General
industrial
machine)
EN61800-3
(Motor
control unit)
EN61000-4-2
Radiated radio-frequency magnetic
field immunity test
(Example) Simulation of immunity from digital
wireless transmitters
EN61000-4-3
Electrical fast transient/burst
immunity test
(Example) Withstand level of noise from relays
or connecting/disconnecting live wires
EN61000-4-4
Immunity to conducted disturbance
induced by radio-frequency
magnetic field
(Example) Withstand level of noise entering
through power line, etc.
EN61000-4-6
Power supply frequency field
immunity test
(Example) 50/60Hz power frequency noise
EN61000-4-8
Immunity test for voltage dip, short-
time power failure and voltage
fluctuation
(Example) Power voltage drop withstand level
EN61000-4-11
Surge immunity test
(Example) Withstand level of noise caused by
lightning
EN61000-4-5
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......