9.4.4 Troubleshooting for Each Alarm No.
Alarm No.
8
Watchdog :
The system does not operate correctly.
Investigation details
Investigation results
Remedies
1
Check whether the PFU software version was
changed recently.
Changed.
Change the S/W version back to the original.
Not changed.
Check the investigation item No. 2.
2
Check the reproducibility.
The error is always repeated.
Replace the power backup unit.
The state returns to normal once, but the error
occurs sometimes thereafter.
Check the investigation item No. 3.
3
Check if there is any abnormality in the unit's
ambient environment. (Ex. Ambient temperature,
noise, grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
Alarm No.
10
Memory error 1 :
An internal memory error was detected during the power ON self-check.
Investigation details
Investigation results
Remedies
1
Check the reproducibility.
The error is always repeated.
Replace the power backup unit.
The state returns to normal once, but the error
occurs sometimes thereafter.
Check the investigation item No. 2.
2
Check if there is any abnormality in the unit's
ambient environment. (Ex. Ambient temperature,
noise, grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
Alarm No.
11
Memory error 2 :
An error was detected in the internal clock signal.
Investigation details
Investigation results
Remedies
1
Check the investigation items of the alarm No. 10.
Alarm No.
12
Unit ID error :
An error was detected in the internal hardware ID.
Investigation details
Investigation results
Remedies
1
Check the investigation items of the alarm No. 10.
Alarm No.
13
A/D converter error:
An error was detected in the A/D converter, which is used for detecting current and voltage.
Investigation details
Investigation results
Remedies
1
Check the investigation items of the alarm No. 10.
Alarm No.
18
Function selection error :
An error was detected in the settings of DIP or rotary switches.
Investigation details
Investigation results
Remedies
1
Check the settings of switches on the upper part of
the unit.
The switch setting is wrong (disabled setting).
Set the switches correctly.
The switch settings are correct.
Replace the power backup unit.
Alarm No.
19
External emergency stop setting error :
The external emergency stop cancel state was detected although the external emergency stop input is set as disabled.
Investigation details
Investigation results
Remedies
1
Check for a wiring error in connection to the DI1
terminal of CN43.
There is an error in wiring.
Perform wiring correctly.
There is no error in wiring.
Check the investigation item No. 2.
2
Check the reproducibility.
The error is always repeated.
Replace the power backup unit.
The state returns to normal once, but the error
occurs sometimes thereafter.
Check the investigation item No. 3.
3
Check if there is any abnormality in the unit's
ambient environment. (Ex. Ambient temperature,
noise, grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......