MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
352
IB-1501229-F
6.1.8 Spindle Synchronization Adjustment (For Lathe System)
(1) Setting the gain, changeover rotation speed and time constant
[1] For speed loop gain during spindle synchronization, SP005 (speed loop gain 1), SP006 (speed loop lead
compensation 1), and SP007 (speed loop delay compensation 2) are used. For position loop gain, set
standard 15 to SP003 (position loop gain spindle synchronization).
(Note1) To change the setting value of SP003, set the synchronous and basic spindles to the same value.
(Note2)
For the adjustment of SP005, SP006 and SP007, conduct "Adjusting the speed loop parameter" as
a single unit beforehand.
[2] Set rotation speed and time constant during acceleration/deceleration figured by theoretical calculations.
[3] Set "Time-series data measurement" with NC Analyzer as follows and output speed feedback and current
command.
< NC Analyzer setting (Time-series data measurement) >
(2) Confirming the current margin
Perform acceleration/deceleration up to the maximum current speed in spindle synchronization mode. At this time,
confirm that the current value for both acceleration side and deceleration side secure 30% or more of margin in
respect to the current limit value. Also, confirm that no oscillation, etc. are found in the current waveforms.
(Note)
If a margin is 30% or less, extend the acceleration/deceleration time constant so that the margin is
adjusted to 30% or more.
Output waveform example in spindle synchronous mode
Parameter
Setting value
SP003
15
SP036
0000
Get
Waveform type
CH1
Speed feedback (r/min)
CH2
Current command
0
0
Current margin has to
be 30% or more.
Current margin has to be
30% or more.
SP152 or SP186
Speed feedback
Current command
SP153 or SP185
Current limit at accelaration
Current limit at regeneration
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......