MDS-E/EH Series Instruction Manual
7 Troubleshooting
380
IB-1501229-F
Encoder alarm (Servo drive unit)
(Note) A drive unit processes all reset types of alarms as "PR". However, "AR" will be applied according to the encoder.
Alarm number when the encod-
er is connected to CN2 side
2B
2C
2D
2E
48
49
4A
4B
Alarm number when the encod-
er is connected to CN3 side
1B
1C
1D
1E
27
28
29
2A
OSA405
OSA676
Mitsubishi
Electric
Memory
alarm
LED alarm
Data alarm
Encoder
thermal error
-
-
-
-
OSA405ET2AS
OSA676ET2AS
Memory
alarm
LED alarm
Data alarm
Encoder
thermal error
-
-
-
-
OSA24RS
CPU alarm
Waveform
error
Data alarm
Encoder
thermal error
-
-
-
-
MDS-EX-HR
Memory error
-
Data error
-
Scale not
connected
-
-
-
AT343
AT543
AT545
AT1143
ST748
Mitsutoyo
Initialization
error
EEPROM er-
ror
Photoelec-
tric type, stat-
ic capacity
type data
mismatch
ROM/RAM
error
CPU error
Photoelec-
tric type over-
speed
Static capaci-
ty type error
Photoelec-
tric type error
LC195M,
LC495M,
LC291M,
LIC2197M,
LIC2199M
MC15
RCN2590M,
RCN5390M,
RCN5590M,
RCN8390M
ROC425M,
ROC2390M
ECA4000Series
EIB Series
HEIDENHAIN
Initialization
error
EEPROM er-
ror
Relative/ab-
solute posi-
tion data
mismatch
ROM/RAM
error
CPU error
Overspeed Absolute po-
sition data er-
ror
Relative po-
sition data er-
ror
MPRZ scale
Mitsubishi
Heavy Indus-
tries Machine
Tool
Installation
accuracy
fault
-
Detection po-
sition devi-
ance
Scale break-
ing
Absolute po-
sition detec-
tion fault
-
Gain fault
Phase fault
SR67A,
SR75, SR85
SR74, SR77
SR84, SR87
RU77
RS87
Magnescale
Laser diode
error
System
memory error
Encoder mis-
match error
-
-
Over speed Absolute po-
sition data er-
ror
Relative po-
sition data er-
ror
SAM/SVAM/
GAM/LAM/HAM
Series
FAGOR
-
-
Absolute val-
ue detection
error
H/W error
CPU error
-
-
-
RL40N/RA
Series
Renishaw
Initialization
error
-
Absolute po-
sition data er-
ror
-
-
Over speed
-
-
WMFA/WMBA/
WMRA/LMFA/
LMBA Series
(Note)
AMO
Initialization
error
-
Relative/ab-
solute posi-
tion data
mismatch
-
-
Over speed Absolute po-
sition data er-
ror
-
AMS-ABS-3B
Series
Schneeberger
-
-
-
Absolute po-
sition data er-
ror
-
-
-
-
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......