MDS-E/EH Series Instruction Manual
11 Appx. 2: D/A Output Specifications for Drive Unit
481
IB-1501229-F
11.3.2 Spindle Drive Unit Settings
Internal data output (Data No. -1 to 3, 50, 60, 127)
Set when outputting data other than in standard magnification (the magnification is 1). When "0" is set, the
magnification will be 1, which is the same as when "100" is set.
(Example 1) When SP125=1, SP127=50
Commanded motor rotation speed is output to D/A output channel 1 in increments of 2000r/min/V.
(Example 2) When SP126=2, SP128=200
The torque axis current command is output to D/A output channel 2 in increments of 50%/V.
【
#13127
】
SP127 DA1MPY D/A output ch1 output scale
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
【
#13128
】
SP128 DA2MPY D/A output ch2 output scale
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
+2.5
+2.5 [V]
+5 [V]
0 [V]
+4.0
+1.0
+1. 5
- 1. 5
2000r/min/V
50%/V
SP125=0
SP127=50
SP126=2
SP128=200
+3. 6
+1. 7
+1. 3
- 1. 2
0 [V]
+1.1
- 0. 8
SP125=0
SP127=100
+2. 5
+0. 5
- 2. 5
- 0.5
1000r/min/V
+2.5 [V]
0 [V]
+5 [V]
(acceleration)
55%
3000r/min (reverse run)
Example of D/A output waveform: 3000r/min during acceleration and deceleration
《
Speed FB
》
《
Current FB
》
< When 3000r/min is displayed at the setting range of “1000r/min/V” >
When the speed waveform at 3000r/min is measured using a
high-speed waveform recorder with SP127 set to “100”, the data
exceeds the D/A output range (+5.0V for forward run and 0V for
reverse run) at 2500r/min, but it will be cleared immediately and then
the remaining data will be output. Even if the data exceeds the D/A
output range more than one time, it will be cleared and the remains
will be output.
Magnification
change
3000r/min (forward run)
3000r/min (reverse run)
3000r/min (forward run)
(deceleration)
40%
(acceleration)
60%
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......