MDS-E/EH Series Instruction Manual
5 Servo Adjustment
281
IB-1501229-F
5.3.5 Improvement of Protrusion at Quadrant Changeover
The response delay (caused by dead band from friction, torsion, expansion/contraction, backlash, etc.) caused when the
machine advance direction reverses is compensated with the lost motion compensation (LMC compensation) function.
With this, the protrusions that occur at the quadrant changeover in the DBB measurement method, or the streaks that
occur when the quadrant changes during circular cutting can be improved.
DBB: Double Ball Bar
[1] LMC compensation type 2
This is an obsolete compensation method. When performing new adjustment, use LMC compensation type 3.
[2] LMC compensation type 3
In addition to frictional torque influence, this type compensates torsion and expansion/contraction influences in the
machine system in which compensation amount is changed by travel speed. A mechanical system viscosity
coefficient setting further enhances the compensation accuracy even if the travel speed is changed. Adjustment
requires a machine roundness measurement.
[3] LMC compensation type 4
This is used in combination with LMC compensation type 3. Compensation is performed by monitoring path tracking
delay. Therefore, even if the machine friction amount has changed due to aged deterioration, the path tracking
delay is controlled so that it will be minimum.
POINT
1. LMC compensation performs adjustment while measuring the electrical end roundness waveform (encoder position FB).
Disable the NC side machine error compensation (pitch error compensation, relative position compensation, backlash
compensation). All machine error compensation can be disabled at once by setting SV113 to bit7.
2. After the compensation adjustment is completed, adjust the machine error compensation while measuring the machine
error compensation with DBB measurement method, etc.
Compensation
Cutting
direction
Circle cutting path after compensation
Circle cutting path before compensation
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......