MDS-E/EH Series Instruction Manual
7 Troubleshooting
408
IB-1501229-F
Alarm No.
68
Power supply: Watchdog
The system does not operate correctly. LED display is fixed as "8".
Investigation details
Investigation results
Remedies
CV
1
Check the repeatability.
The alarm occurs each time READY is turned
ON.
Replace the unit.
◯
The alarm occurs occasionally.
Check the investigation item No. 2.
2
Check if there is any abnormality in the unit's
ambient environment.
(Ex. Noise, grounding, etc.)
Take remedies according to the causes of the abnormality in the ambient environment.
◯
Alarm No.
69
Power supply: Grounding
The motor power cable is in contact with FG (Frame Ground).
Investigation details
Investigation results
Remedies
SV SP
1
Measure the insulation across the power cables
(U,V,W) for all motors and the ground. (Carry out a
megger test.)
Less than 1M
Ω
. (Grounding)
The motor or power cable may be ground
faulted.
◯
◯
1M
Ω
or more. (Normal)
Check the investigation item No. 2.
2
Has oil adhered on the motor or power cable?
Oil has adhered.
Take measures so that oil does not come in
contact. Check the motor's cannon connector
and the inside of the terminal box, and clean
as necessary.
◯
◯
Oil has not adhered.
Check the investigation item No. 3.
3
Measure the insulation again.
Less than 1M
Ω
. (Grounding)
Replace the motor or cable.
◯
◯
1M
Ω
or more. (Normal)
Check the investigation item No. 2.
4
Measure the resistance across the U, V, W phase
terminals of the servo/spindle drive unit and the
ground.
(Note) Do not measure the insulation as the unit is
damaged.
Less than 100k .
Replace the drive unit.
◯
◯
100k or more.
Replace the power supply unit.
5
Check whether there is any axis in which alarm 24
has occurred.
There is an axis in which alarm has occurred. Check the alarm No. "24" items.
◯
◯
There is no axis in which alarm has occurred. Check the investigation item No. 2.
Alarm No.
6A
Power supply: External contactor welding
A contact of the external contactor is welding.
Investigation details
Investigation results
Remedies
CV
1
Check whether any alarm has occurred on the drive
unit side.
An alarm has occurred.
Remove the cause of the alarm on the drive
side, and check the investigation item No. 2.
◯
An alarm has not occurred.
Check the investigation item No. 2.
2
Check whether the contactor's contact has melted.
The contactor has melted.
Replace the contactor.
◯
The contactor has not melted.
Check the investigation item No. 3.
3
Check that the contactor excitation wiring is
correctly connected from the power supply unit's
MC1 terminal.
The connection is correct.
Correctly connect.
◯
The connection is incorrect.
Replace the power supply unit.
Alarm No.
6B
Power supply: Rush circuit error
A thyristor for rush short circuit is ON when rushing.
Investigation details
Investigation results
Remedies
CV
1
Check whether any alarm has occurred on the drive
unit side.
An alarm has occurred.
Remove the cause of the alarm on the drive
side, and then carry out the investigation
details 2.
◯
An alarm has not occurred.
Check the investigation item No. 2.
2
Check the repeatability.
The alarm occurs each time READY is turned
ON.
Replace the unit.
◯
The alarm occurs occasionally.
Check the investigation item No. 3.
3
Check if there is any ground fault in the motor.
Check the investigation item of Alarm No. 69. Take remedies of Alarm No. 69.
◯
No ground fault.
Check the investigation item No. 4.
4
Check if there is any abnormality in the unit's
ambient environment.
(Ex. Noise, grounding, etc.)
Take remedies according to the causes of the abnormality in the ambient environment.
◯
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......