MDS-E/EH Series Instruction Manual
4 Setup
168
IB-1501229-F
< Setting parameters for the encoder with semi/full-closed loop control >
Set parameters depending on the encoder configured in the machine. For semi-closed loop, set the same value to the
main side and the sub side. For full-closed loop, set the encoder of the main side and the sub side.
【
#13019(PR)
】
SP019 RNG1 Sub side encoder resolution
[For semi-closed loop]
Set the same value as SP020 (RNG2). (Refer to the explanation of SP020.)
[For full-closed loop]
Set the number of pulses per revolution of the machine side encoder.
When using the encoder interface unit MDS-EX-HR, use this with SP097 (RNG1ex).
Encoder
OSE-1024 (ABZ pulse): SP019=4096, SP097=-1
TS5690( 64 teeth): SP019 = 2000, SP097=0
TS5690( 90 teeth): SP019 = 2880, SP097=0
TS5690(128 teeth): SP019 = 4000, SP097=0
TS5690(192 teeth): SP019 = 6000, SP097=0
TS5690(256 teeth): SP019 = 8000, SP097=0
TS5690(384 teeth): SP019 =12000, SP097=0
ERM280(1200 teeth): SP019 = 4800, SP097=0
ERM280(2048 teeth): SP019 = 8000, SP097=0
MPCI : SP019 = 7200, SP097=0
MBE205: SP019 = 2000, SP097=0
GEL2449M(524,288(p/rev)): SP019=0, SP097=8
---Setting range---
When SP097=0, the setting range is from 0 to 32767 (kp)
When SP097
≠
0, the setting range is from 0 to 65535 (p)
【
#13020(PR)
】
SP020 RNG2 Main side encoder resolution
Set the number of pulses per revolution of the motor side encoder. Set the standard parameters for
the motor with frame.
---Setting range---
When SP098=0, the setting range is from 0 to 32767 (kp)
When SP098
≠
0, the setting range is from 0 to 65535 (p)
【
#13097
】
SP097 RNG1ex Extension sub side encoder resolution
When setting the machine side encoder resolution in pulse (p) unit, set the number of pulses to four
bite data of SP097 (high-order) and SP019 (low-order) in pulse (p) unit.
When SP097=0, the setting unit of SP019 is (kp).
Refer to SP019 for details.
Related parameters: SP019, SP020, SP098
---Setting range---
-1 to 32767
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......