MDS-E/EH Series Instruction Manual
5 Servo Adjustment
258
IB-1501229-F
5.2.4 OMR-FF Function
OMR-FF control improves the inner rounding amount of the arc, corner tracking error, or path vibration, etc. more
comprehensively than conventional high-speed high-accuracy control by creating appropriate feed forward command for
each of position, speed, and current depending on the vibration characteristics of the control target.
Feed forward is performed inside the drive unit according to the scale model and inertia setting in the OMR-FF
generation part, and can independently set the command trackability with the scale model position loop gain (PGM) and
the servo rigidity with the position control gain (PGN). This enables the higher and smoother trackability to the position
command.
This function can be highly effective for linear servo, direct drive motors, or general motors in semi-closed loop control.
OMR-FF control option for NC side is required when using this function.
OMR-FF function adjustment parameters
No.
Abbrev.
Parameter name
Setting range (unit)
SV106
PGM
OMR-FF scale model gain
0 to 300 (rad/s)
SV112
IFF
OMR-FF current feed forward gain
0 to 32767 (0.01%)
CAUTION
1. Always set the load inertia scale when using this function because the parameter is crucial to this function.
If this function is enabled, the estimated inertia value is displayed as "0". If setting the load inertia scale, be sure to set it
before the adjustment for OMR-FF function.
2. Disable SHG control when using this function.
S
+
-
+
-
+
+
+
SV037
(PGN)
(PGM)
(load inertia)
Position
command
Scale
model
OMR-FF generation part
Position
control
Speed
control
Position FF
Speed FF
Current FF
Control target
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......