Set the torque limit value when the torque limit (spindle control input 1/bitA, 9, 8) is set to "011" (TL3, TL2,
TL1 = 011).
---Setting range---
0 to 999 (Short-time rated %)
Not used.
Set the single-rotation position alignment completion width for phase alignment and changing from non-in-
terpolation to spindle synchronization mode during rotation.
Set the rotation error that is required to the machine.
When the setting value decreases, the rotation error will decrease, but the cycle time (settling time) will get
longer. The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
Set the scale for SP016 (DDT) to change the deceleration rate only during rotation command (command F
∆
T
≠
0).
When the setting value increases, the single-rotation position alignment will be completed faster, but the im-
pact to the machine will also increase. When not using, set to "0".
---Setting range---
0 to 255 (1/16-fold)
Set this parameter to adjust the deceleration time by changing the current limit value during deceleration de-
pending on the motor speed.
As shown below, set the lower limit rate of the current limit in SP071 (DIQM), and use with SP072 (DIQN).
When DIQM is set to 100%, the standard current limit value in deceleration (SP152) is applied.
---Setting range---
0 to 999 (%)
Set this parameter to adjust the deceleration time by changing the current limit value during deceleration de-
pending on the motor speed.
As shown below, set the lower limit rate of the current limit in SP071 (DIQM), and use with SP072 (DIQN).
When DIQM is set to 100%, the standard current limit value in deceleration (SP152) is applied.
---Setting range---
1 to 32767 (r/min)
#13067
SP067 TLM3
Torque limit 3
#13068
SP068
#13069
SP069 PCMP
Phase alignment completion width
#13070
SP070 KDDT
Phase alignment deceleration rate scale
#13071
SP071 DIQM
Variable current limit during deceleration, lower limit
value
#13072
SP072 DIQN
Variable current limit during deceleration, break point
speed
DIQN
0
DIQM
100%
SP152
Motor speed
DIQN
0
DIQM
100%
SP152
Motor speed
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......