MDS-E/EH Series Instruction Manual
7 Troubleshooting
402
IB-1501229-F
(Note)
NR and PR resetting are not possible when the overload level is 50% or more. Do not forcibly reset (AR) by turning
the unit power OFF. If AR resetting is used at 50% or higher, the level is set to 80% when the power is turned ON
next. (Servo)
Alarm No.
4F
Instantaneous power interrupt
The control power supply has been shut down for 50ms or more.
Investigation details
Investigation results
Remedies
SV SP
1
Check the repeatability.
The alarm occurs occasionally.
Check the power facilities.
-
◯
Check the wiring of the control power.
Alarm No.
50
Overload 1
Overload detection level became over 100%. The motor or the drive unit is overloaded.
Investigation details
Investigation results
Remedies
SV SP
1
Check the overload parameters.
Servo:SV021, SV022
Spindle:SP021,SP022
The standard values (below) are not set.
Servo:SV021 = 60, SV022 = 150
Spindle:SP021=60,SP022=120
IPM:SP021=300,SP022=100
Set the standard values.
◯
◯
The standard values are set.
Investigate item 2.
2
Check the items below displayed on the drive
monitor screen during operation.
<Servo>
Max.current 3 (%)
Overload(%)
<Spindle>
Load meter(%)
Perform the machining such as rapid
traverse, where an alarm occurs. The
examples are below.
<Servo>
[1] Max.current 3 constantly displays the
maximum value.
[2] Overload increases at a rapid speed.
<Spindle>
[1] The time to display 120% lasts long.
[2] The value is higher than normal.
Servo
[1] Mount a smaller workpiece.
[2] Increase the time constant.
[3] Check the investigation item No.6.
◯
◯
Spindle
[1] Lower the cutting amount.
[2] Extend the cycle time.
The value is within the supposed level and
there is no problem.
Investigate item 3.
3
Check whether machine resonance is occurring.
Check for vibration and abnormal noise at the
spindle and table.
Resonance is occurring when a tool or
workpiece is mounted or during machining.
(The load inertia changes)
Adjust the parameters.
[1] Set the optimal notch filter.
[2] Lower VGN1 (SV005,SP005).
◯
◯
Resonance is not occurring.
Investigate item 4.
4
Check whether the shaft sways when the motor is
stopped.
"Hunting" of the spindle
"Vibration" of the table
The motor is hunting.
Adjust the parameters.
[1] Increase VGN1 (SV005, SP005).
[2] Lower VIA (SV008, SP008).
◯
◯
The motor is not hunting.
Servo: Investigate item 5
Spindle: Investigate item 7
5
Check the brake operation.
[1] Check the brake relay.
[2] Check the connector (CN20) connection.
The motor brakes are not released.
Correct the faulty section.
◯
The motor brake operation is normal.
Investigate item 6.
6
Check the load current with the NC Servo Monitor,
and investigate the machine load.
The cutting load is large.
Lower the cutting load.
◯
There is interference with the positioning pin.
When using the positioning pin, turn the
servo OFF when stopped.
An excessive force is applied from the
machine.
Check whether the ball screw is bent, or
whether there is a fault in the guide.
The machine load is not large.
Investigate item 8.
7
Check the PLG output waveform.
TS5690 cannot be checked.
There is a problem.
Adjust the PLG output waveform.
For TS5690, reinstall.
◯
Normal
Investigate item 8.
8
Confirm the motor capacity selection again.
The motor performance is insufficient.
Lower the acceleration/deceleration rate or
cutting load.
◯
◯
The motor performance is sufficient.
Check the tool mounted on the spindle.
- The service life is reached.
Increase the number of teeth (chips) of the
milling cutter, etc.
Investigate item 9.
9
Try replacing the drive unit.
Improved.
Use as it is.
◯
◯
Not improved.
Replace the motor.
Содержание MDS-E
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 31: ......
Страница 32: ...1 IB 1501229 F 1 Installation ...
Страница 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Страница 132: ...101 IB 1501229 F 3 Safety Function ...
Страница 142: ...111 IB 1501229 F 4 Setup ...
Страница 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Страница 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Страница 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Страница 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Страница 404: ...373 IB 1501229 F 7 Troubleshooting ...
Страница 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Страница 456: ...425 IB 1501229 F 8 Maintenance ...
Страница 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Страница 476: ...445 IB 1501229 F 9 Power Backup System ...
Страница 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Страница 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Страница 513: ...MDS E EH Series Instruction Manual 11 Appx 2 D A Output Specifications for Drive Unit 482 IB 1501229 F ...
Страница 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Страница 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Страница 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Страница 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Страница 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Страница 545: ...MDS E EH Series Instruction Manual 15 Appx 6 Higher Harmonic Suppression Measure Guidelines 514 IB 1501229 F ...
Страница 550: ......
Страница 554: ......