SDA Operator’s Manual
6. Touch
the
Delta
button
to set up a nominal range, plus or minus a delta value in
seconds. Touch inside the
Nominal Width
and
Delta
data entry fields and enter values using
the pop-up numeric keypads.
7. Touch
the
Limits
button
to set up a precise range. Touch inside the
Lower Limit
and
Upper Limit
data entry fields and enter values using the pop-up numeric keypads.
Or
touch the
OutOfRange
button and perform the same Delta or Limits setup as for
InRange triggering.
Qualified Trigger
How Qualified Triggers Work
Use a signals transition above or below a given level (its validation) as an enabling (qualifying)
condition for a second signal that is the trigger source. These are Qualified triggers. For Edge
Qualified triggers (the default) the transition is sufficient and no additional requirement is placed
on the first signal. For State Qualified triggers the amplitude of the first signal must remain in the
desired state until the trigger occurs. A qualified trigger can occur immediately after the validation,
or following a predetermined time delay or number of potential trigger events. The time delay or
trigger count is restarted with every validation.
Within Time
creates a time window within which a trigger can occur.
Wait Time
determines a delay from the start of the desired pattern. After the delay
(timeout) and while the pattern is present, a trigger can occur. The timing for the delay is restarted
when the selected pattern begins.
Events
determines a minimum number of events of the trigger source. An event is
generated when a trigger source meets its trigger conditions. On the selected event of the trigger
source and while the pattern is present, a trigger can occur. The count is initialized and started
whenever the selected pattern begins, and continues while the pattern remains. When the
selected count is reached, the trigger occurs.
SDA-OM-E Rev H
89
Содержание SDA
Страница 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Страница 148: ...Standard Horizontal Parameter Help Markers Standard Vertical Parameter Help Markers 148 SDA OM E Rev H ...
Страница 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Страница 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Страница 232: ...In this figure the panel has been pasted onto the Excel sheet for comparison 232 SDA OM E Rev H ...
Страница 243: ...SDA Operator s Manual This example used the CORREL Array1 Array2 function of Excel as depicted below SDA OM E Rev H 243 ...
Страница 246: ...246 SDA OM E Rev H ...
Страница 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Страница 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Страница 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Страница 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Страница 328: ...328 SDA OM E Rev H ...
Страница 394: ...394 SDA OM E Rev H ...
Страница 395: ...SDA Operator s Manual SDA OM E Rev H 395 ...