SDA Operator’s Manual
SDA-OM-E Rev H
137
Cursors Setup
Quick Display
At any time, you can change the display of cursor types (or turn them off) without invoking the
"Cursors Setup" dialog as follows:
1. In the menu bar, touch
Cursors
, then
Off
,
Abs Horizontal
,
Rel Horizontal
,
Abs Vertical
, or
Rel Vertical
.
2. The cursors displayed will assume the positions previously set up. If you want to change their
position or measurement mode, in the menu bar touch
Cursors
, then
Cursors Setup
in the
drop-down menu.
Full Setup
1. In the menu bar, touch
Cursors
, then
Cursors Setup
. The "Standard Cursors" dialog opens.
2. In the dialog area, touch the
Cursors On
check box to display them.
3. Touch one of the
Horizontal
or
Vertical
mode buttons:
Relative
or
Absolute
.
4. If you chose a Relative mode, also touch a readout parameter button: Y position, delta Y, or
slope.
5. If you chose a Relative mode, touch inside the
Position 1
and
Position 2
data entry fields
and type in a value for each cursor. You can also use the Cursors knobs on the front panel to
place the cursors. If you chose an Absolute mode, do the same for your single cursor.
6. If you chose a Relative mode and you would like both cursors to move in unison as you
adjust the position, touch the
Track
check box to enable tracking.
Overview of Parameters
Parameters are measurement tools that determine a wide range of waveform properties. Use
them to automatically calculate many attributes of your waveform, like rise-time, rms voltage, and
peak-to-peak voltage, for example.
There are parameter modes for the amplitude and time domains, custom parameter groups, and
parameters for pass and fail testing. You can make common measurements on one or more
waveforms.
Turning On Parameters
1. Touch
Measure
in the menu bar, then
Measure Setup...
in the drop-down menu.
2. Touch
inside
the
On
checkbox for each parameter you want to display.
Содержание SDA
Страница 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Страница 148: ...Standard Horizontal Parameter Help Markers Standard Vertical Parameter Help Markers 148 SDA OM E Rev H ...
Страница 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Страница 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Страница 232: ...In this figure the panel has been pasted onto the Excel sheet for comparison 232 SDA OM E Rev H ...
Страница 243: ...SDA Operator s Manual This example used the CORREL Array1 Array2 function of Excel as depicted below SDA OM E Rev H 243 ...
Страница 246: ...246 SDA OM E Rev H ...
Страница 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Страница 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Страница 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Страница 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Страница 328: ...328 SDA OM E Rev H ...
Страница 394: ...394 SDA OM E Rev H ...
Страница 395: ...SDA Operator s Manual SDA OM E Rev H 395 ...