Adjusting the Waveform's Position
Turn the vertical offset adjust knob directly above the channel button whose waveform you want
to move vertically.
Or, you can touch inside the
Offset
field and type in a value on the pop-up keypad. To set the
vertical offset to zero, touch the
Zero Offset
button directly below the
Offset
field.
Coupling
The choices of coupling are as follows:
•
DC 50 (all instruments)
•
GROUND
(all
instruments)
•
DC 1 M (WavePro & WaveRunner instruments)
•
AC 1 M (WavePro & WaveRunner instruments)
Overload Protection
The maximum input voltage is 4 V peak. Whenever the voltage exceeds this limit, the coupling
mode automatically switches from DC 50
Ω
to GROUND. You will then have to manually reset
the coupling to DC 50
Ω
, as described next.
Coupling Setup
1. In the menu bar, touch the
Vertical
button, then
Channel X Setup...
in the drop-down menu.
2. Touch
inside
the
Coupling
field and select a coupling mode from the pop-up menu.
Probe Attenuation
Setting Probe Attenuation
LeCroy's ProBus system automatically senses probes and sets their attenuation for you. If you
want to set the attenuation manually,
1. In the menu bar, touch
Vertical
, then select a channel from the drop-down menu.
2. Touch
inside
the
Probe Atten.
data entry field
. Touch a divide-by menu
selection or touch
Var
(variable). If you choose
Var
, type in a value using the pop-up numeric
keypad.
68
SDA-OM-E Rev H
Содержание SDA
Страница 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Страница 148: ...Standard Horizontal Parameter Help Markers Standard Vertical Parameter Help Markers 148 SDA OM E Rev H ...
Страница 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Страница 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Страница 232: ...In this figure the panel has been pasted onto the Excel sheet for comparison 232 SDA OM E Rev H ...
Страница 243: ...SDA Operator s Manual This example used the CORREL Array1 Array2 function of Excel as depicted below SDA OM E Rev H 243 ...
Страница 246: ...246 SDA OM E Rev H ...
Страница 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Страница 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Страница 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Страница 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Страница 328: ...328 SDA OM E Rev H ...
Страница 394: ...394 SDA OM E Rev H ...
Страница 395: ...SDA Operator s Manual SDA OM E Rev H 395 ...