SDA Operator’s Manual
4. In the "Px" dialog, touch the
math on parameters
button
. The
Source
field will
expand to two fields.
5. Touch
inside
the
Source1
and
Source2
fields and select the parameters you want to apply
math to (P1 to Px). If you are applying math to a single parameter (for example, invert), just
touch inside the
Source1
field and select a parameter (P1 to Px).
6. Touch
inside
the
Math Operator
field and select
P Script
from the
Select
Measurement
menu.
7. In the "Script Math" dialog, touch inside the Script Language field and select either
VBScript
or
JScript
from the pop-up menu.
8. Touch
the
Edit Code
button; the Script Editor window opens. You can enter code in this
window or call up an existing script from a file storage location. If you create your script in this
window, you can then export it and save it to file.
Measure Gate
Using Measure Gate, you can narrow the span of the waveform on which to perform parameter
measurements, allowing you to focus on the area of greatest interest. You have the option of
dragging the gate posts horizontally along the waveform, or specifying a position down to
hundredths of a division. The default starting positions of the gate posts are 0 div and 10 div,
which coincide with the left and right ends of the grid. The gate, therefore, initially encloses the
entire waveform.
Note:
If you have Grid On Top enabled, you will not see the gate posts in their default position at each end of the grid. But
if you touch either end of the grid, a drag cursor
will appear, indicating that you have control of the post and can
now drag it.
SDA-OM-E Rev H
145
Содержание SDA
Страница 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Страница 148: ...Standard Horizontal Parameter Help Markers Standard Vertical Parameter Help Markers 148 SDA OM E Rev H ...
Страница 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Страница 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Страница 232: ...In this figure the panel has been pasted onto the Excel sheet for comparison 232 SDA OM E Rev H ...
Страница 243: ...SDA Operator s Manual This example used the CORREL Array1 Array2 function of Excel as depicted below SDA OM E Rev H 243 ...
Страница 246: ...246 SDA OM E Rev H ...
Страница 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Страница 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Страница 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Страница 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Страница 328: ...328 SDA OM E Rev H ...
Страница 394: ...394 SDA OM E Rev H ...
Страница 395: ...SDA Operator s Manual SDA OM E Rev H 395 ...