SDA Operator’s Manual
•
External trigger input range:
AUX (±0.4 V); AUX X10 (±0.04 V); AUX /10 (±4 V) Not
available on SDA 6000A, SDA 5000A, SDA 4000A
Automatic Setup
•
Auto Setup:
Automatically sets timebase, trigger, and sensitivity to display a wide range of
repetitive signals.
•
Vertical Find Scale:
Automatically sets vertical sensitivity and offset for the selected
channels to display a waveform with maximum dynamic range.
Probes
•
Probes:
A variety of optional passive and active probes are available.
•
Probe System:
ProLink with ProBus automatically detects and supports a variety of
compatible probes; Supports ProLink SMA or BNC input adapters.
•
Scale Factors:
Automatically or manually selected depending on probe used.
Basic Triggers
Edge/Slope/Line:
Triggers when signal meets slope and level condition.
SMART Triggers
•
State or Edge Qualified:
Triggers on any input source only if a defined state or edge
occurred on another input source. Delay between sources is selectable by time or events
•
Dropout:
Triggers if signal drops out for longer than selected time between 2 ns and 20 s
•
Pattern Logic:
Combination (AND, NAND, OR, NOR) of 5 inputs (maximum of 3 or 4 inputs;
External Trigger not available on the SDA 6000A, SDA 5000A, and SDA 4000A; 4, 3, or 2 Ch
+ External Trigger on SDA 18000/13000/11000/9000). Each source can be high, low, or don't
care. Triggers at the start or end of the pattern.
SMART Triggers with Exclusion Technology
•
Glitch:
Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or
on intermittent faults.
•
Signal or Pattern Width:
Triggers on positive or negative pulse widths selectable from 600
ps to 20 s or on intermittent faults.
•
Signal or Pattern Interval:
Triggers on intervals selectable between 2 ns and 20 s.
SDA-OM-E Rev H
31
Содержание SDA
Страница 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Страница 148: ...Standard Horizontal Parameter Help Markers Standard Vertical Parameter Help Markers 148 SDA OM E Rev H ...
Страница 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Страница 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Страница 232: ...In this figure the panel has been pasted onto the Excel sheet for comparison 232 SDA OM E Rev H ...
Страница 243: ...SDA Operator s Manual This example used the CORREL Array1 Array2 function of Excel as depicted below SDA OM E Rev H 243 ...
Страница 246: ...246 SDA OM E Rev H ...
Страница 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Страница 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Страница 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Страница 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Страница 328: ...328 SDA OM E Rev H ...
Страница 394: ...394 SDA OM E Rev H ...
Страница 395: ...SDA Operator s Manual SDA OM E Rev H 395 ...